Houston Fire Code §1203.4 requires emergency and standby power systems to be maintained under NFPA 110 and NFPA 111 on the schedule in HFD LSB Standard No. 02. LSB 02 §2.4.3.2 calls for an annual load test by an authorized generator service company: 25% of nameplate for 30 minutes, 50% for 30 minutes, then 75% for 60 minutes, two continuous hours with cold starts.
Find fire safety service providers in Houston, Texas and compare their bids. Ask providers to document work against the applicable Houston Fire Code §1203.4 / LSB 02 §2.4.3.2 requirements.
Free to post · No commitment
Annual generator load testing proves the emergency power supply system can carry its load for the required time. LSB 02 §2.4.2.2 also requires a monthly 30-minute run check under load with a written record, which building staff may perform.
Required frequency: Annual 2-hour load test (LSB 02 §2.4.3.2); monthly 30-minute run check with a written record (LSB 02 §2.4.2.2)
LSB 02 §2.4.3.2 says an authorized generator service company. This is not an SFMO/TDI fire-protection license class, so review the company's documentation, insurance and service area on its profile before you hire.
Once a year under HFD LSB 02 §2.4.3.2, by an authorized generator service company, plus a monthly 30-minute run check under load with a written record (§2.4.2.2). Houston Fire Code §1203.4.3 requires the records to be kept.
LSB 02 §2.4.3.2 says an authorized generator service company. This is not an SFMO/TDI fire-protection license class, so review the company's documentation, insurance and service area on its profile before you hire.
FireMarket does not publish a fixed price for this service. Request a quote; price depends on system size and condition, site access, deficiencies found, parts, after-hours work, and the reports or tags required.
Yes. Ask the contractor to price inspection and testing separately from repair or replacement line items, so you can approve corrective work after seeing the findings.
Create a free owner account, post the job, compare bids, and hire on FireMarket. Bidding is capacity-aware, and time-on-site check-in and check-out can document the visit. Booking is not instant.
Add the system and its last test date to your property's compliance calendar. It calculates the next due date from the cited interval, sends reminders, and keeps the report for your proof packet.
Sources: HFD LSB Standard No. 02, Rev. 05 (eff. 01/01/2024) · Houston Fire Code Chapter 12, §1203. FireMarket does not file or submit records to SFMO, TDI, TCEQ, or the AHJ.
Review the provider's available license, insurance, trade, and service-area evidence before making a selection.
Describe the property, trade, scope, and timing so matched providers can respond with relevant bids.
Keep job records and provider documents together for your own review and follow-up.
Create a free account, post your job, and invite providers to submit comparable quotes.
Get Started Free