Houston restaurant grease trap inspection requirements
Inside Houston city limits, a restaurant's grease trap or interceptor must be fully pumped out at least once every 90 days, and sooner when 25% or more of its wetted height holds grease, oil, solids or floating material (Houston Code of Ordinances §47-512). Only a waste transporter permitted by the Houston Health Department may clean it. You sign the manifest at every pump-out and keep the returned copies on site for 5 years, and the Health Department inspects grease traps without notice, at least once a year.
Last updated
The rules at a glance
- Pump-out at least every 90 days: each interceptor or holding tank must be fully evacuated at least once every 90 days (§47-512(b)).
- Sooner when needed: more often than every 90 days when 25% or more of the wetted height contains floating materials, sediment, oils or greases, when the discharge exceeds the city's limit, or when the site has a history of non-compliance (§47-512(c)).
- Whole trap, every time: the entire contents must leave the site. Mobile processors that separate or de-water the waste and leave part of it behind are prohibited (§47-512(h), §47-545).
- Discharge limit: no more than an average of 200 mg/L of fats, oils or grease into the sanitary sewer (§47-514(a)).
- Permit: a restaurant's Fats, Oils and Grease (FOG) generator permit is valid for one year from the food dealer permit issue date and must be renewed every year (Houston Health Department).
- New buildings: commercial facilities such as restaurants, cafeterias, bars and hotels whose building permit was applied for after August 31, 2006 must install and maintain an interceptor with a sample well the health officer can reach (§47-513(a)).
Notice of Waiver: when 90 days can stretch, and the 180-day limit
A restaurant can ask the Houston Health Department to waive the 90-day rule by filing a Notice of Waiver. The waiver takes effect unless the health officer denies it within 30 days of receiving it, and it stays in effect until revoked for a violation (§47-512(e)).
On the form, the restaurant certifies it has had no overflow or discharge at the site in the previous 12 months, and its transporter certifies that the reduced cleaning frequency keeps the effluent within the discharge limits or keeps less than 25% of the trap's wetted height full of grease and solids (§47-512(e)).
Even with an approved waiver, the grease trap must be fully evacuated, cleaned, inspected and, if needed, repaired at least once every 180 days (§47-512(f)).
Who can clean a grease trap in Houston
Only a waste transporter permitted by the Houston Health Department may clean your interceptor. The Health Department publishes a list of permitted service companies.
Do not let a truck pump your trap unless it displays current and valid City registration decals (§47-511). The decals are on both doors and the back of the tank, and show the company's permit number, truck number and current permit year; you can also ask to see the driver's City-issued identification card (Houston Health Department FAQ).
To get the permit, a transporter files driver's licenses, proof of financial responsibility for each vehicle, a City of Houston Waste Transportation Permit Bond of $150,000 or $1,000,000 of pollution liability coverage, and its TCEQ letter of registration, and its vehicles are inspected by the City (Houston Health Department).
The manifest: sign it, get it back, keep it 5 years
- Before the hauler leaves, check that the trap is clean and completely empty, the sample well is clean, and the trap's correct capacity is written on the manifest (Houston Health Department).
- Complete and sign the generator's part of the manifest before any waste is removed (§47-521), and keep your generator copy.
- The transporter must return the generator return copy within 15 days of the pump-out (§47-533).
- If it does not arrive within 15 days, file a copy of your generator copy with a signed affidavit at the office the health officer names, within ten business days after those 15 days (§47-523).
- Keep the generator return copy on site for 5 years, at a location in the county, and hand it over immediately when an inspector asks (§47-522).
What a Houston grease trap inspection looks like
The Health Department inspects every establishment with an interceptor on a routine basis or after a complaint, with no advance notice (Houston Health Department). The code requires inspections as often as needed and at least once a year, including a check of your cleaning frequency (§47-561).
Have these ready for the investigator (Houston Health Department):
- Your original Fats, Oils and Grease permit.
- Yellow and white copies of your waste manifests for the past 5 years.
- Invoices from a permitted biological pretreatment company, if you use one.
- Your approved Notice of Waiver, if you have one.
- Copies of previous inspections.
Fines
- Citation fines for Chapter 47, Article XI violations range from $250 to $2,000 per violation (Houston Health Department).
- Exceeding the discharge limits in §47-514 is punishable by a fine of up to $4,000 (§47-514(b)).
- If the health officer finds a restaurant caused a sanitary sewer blockage, the fine is at least $1,000 for the first violation and $1,500 for a second within 12 months; each later violation within 12 months is up to $2,000, and each day a violation continues is a separate offense (§47-515(b)).
Fryer oil is a separate service
Used fryer grease and rendering oil must be picked up by a private disposal company. The Health Department is explicit that it cannot be poured down a drain, into the grease trap, into a ditch or down a storm drain (Houston Health Department FAQ).
Outside Houston city limits
These rules are the City of Houston's and apply to interceptors inside the incorporated city limits (Houston Health Department). If your restaurant is in unincorporated Harris County or another city, ask that city or your utility district which grease trap rules apply.
How FireMarket helps restaurants stay on schedule
- Post a grease trap job for free and compare bids from haulers. FireMarket checks a hauler's City of Houston permit manually against the Health Department's permitted service-company list and shows the permit number on the bid, quote and manifest.
- The free restaurant compliance calendar in the owner dashboard defaults grease trap pump-outs to every 90 days, sends reminders, and stores uploaded manifests and service reports with a five-year retention date.
- Share uploaded manifests as a proof packet by a link you can revoke. FireMarket does not file or submit records to the City of Houston, TCEQ or any authority.
Frequently asked questions
What are the Houston restaurant grease trap inspection requirements?
Inside Houston city limits, pump the grease trap out completely at least every 90 days (sooner when 25% or more of its wetted height holds grease or solids), use only a Houston Health Department permitted transporter, sign the manifest at every pump-out and keep the returned copy on site for 5 years. The Health Department inspects at least once a year without notice and asks for your Fats, Oils and Grease permit, 5 years of manifests, any Notice of Waiver and previous inspections (Houston Code of Ordinances §§47-511, 47-512, 47-522, 47-561; Houston Health Department).
How often must a restaurant grease trap be cleaned in Houston?
At least once every 90 days inside Houston city limits, and sooner if 25% or more of the trap's wetted height holds grease, oil, solids or floating material (Houston Code of Ordinances §47-512(b) and (c)).
Can a Houston restaurant go longer than 90 days between pump-outs?
Only with an approved Notice of Waiver from the Houston Health Department, and even then the trap must be fully evacuated, cleaned and inspected at least once every 180 days (§47-512(e) and (f)).
What does the Houston grease trap inspector ask for?
Your original Fats, Oils and Grease permit, yellow and white copies of your waste manifests for the past 5 years, pretreatment invoices if you use biological pretreatment, your Notice of Waiver if you have one, and copies of previous inspections (Houston Health Department).
How long do I keep grease trap manifests in Houston?
Keep the generator return copy on site for 5 years from the pump-out date, at a location within the county, and produce it immediately on request (§47-522).
Who is allowed to pump my grease trap?
Only a waste transporter permitted by the Houston Health Department, in a truck showing current and valid City registration decals (§47-511; Houston Health Department FAQ).
Are grease haulers licensed by the State Fire Marshal?
No. Grease haulers are City of Houston permitted waste transporters, with a TCEQ letter of registration filed as part of the City permit. The State Fire Marshal's Office (SFMO/TDI) licenses fire protection work such as sprinkler, alarm, extinguisher and kitchen suppression systems, not grease hauling.
Who inspects restaurant grease traps in Houston?
The Houston Health Department. It inspects every establishment with an interceptor on a routine basis or after a complaint, with no advance notice, and the code requires inspections at least once a year (Houston Code of Ordinances §47-561; Houston Health Department).
Sources
- Houston Code of Ordinances, Ch. 47, Art. XI, Div. 9 (§§47-511 to 47-566)
- Houston Health Department: Special Waste Generators
- Houston Health Department: Special Waste Service Companies (permitted transporter list)
- Houston Health Department: Waste Generator's Frequently Asked Questions (PDF)
- Houston Health Department: Notice of Waiver application (PDF)
Sources checked 2026-11-12. Informational only, not legal advice; confirm requirements with your AHJ.
Next step: post the grease trap job and compare bids on FireMarket
Post the grease trap job on FireMarket USA for free (no card needed to post) and compare bids from Houston haulers. Grease haulers are City of Houston permitted waste transporters, not SFMO/TDI licensees: FireMarket checks the hauler's City permit against the Houston Health Department's permitted service-company list and shows the permit number on the bid, quote and manifest.
Post a grease trap job free