How often must a fire sprinkler system be inspected in Texas?

In Texas, fire sprinkler systems are inspected, tested and maintained on the NFPA 25 (2020 edition) schedule, which the State Fire Marshal adopted in 28 TAC §34.707: some parts weekly or monthly, others quarterly, a full inspection and test annually, and longer tests every 3 and 5 years, with a light blue SFMO tag on each riser after every scheduled service (28 TAC §34.720), and FireMarket USA is where you post the sprinkler inspection, repair, service call, installation or replacement free and get bids from licensed Texas contractors. Inside the City of Houston, a wet-pipe system also gets a written monthly and quarterly visual inspection and an annual inspection tagged by a licensed sprinkler company (HFD LSB Standard No. 02, Rev. 05, §2.5.1).

Last updated · Last checked

Post a sprinkler inspection job free

NFPA 25 sprinkler schedule at a glance

As summarized by NFPA. Exact tasks depend on the system type and its components; NFPA 25-2020 is the edition Texas adopted.

How oftenInspectionsTests
WeeklyControl valves (monthly if locked, quarterly if electrically supervised); reduced-pressure backflow assemblies—
MonthlyGauges; dry-pipe valve exterior—
QuarterlyAlarm valve exterior, fire department connection, supervisory devices, waterflow alarm devices—
Semiannually—Control valve supervisory devices; waterflow alarm devices
AnnuallyDry-pipe valve interior; sprinklers (from the floor); hangers and braces; hydraulic design signControl valves; backflow assemblies; main drain (quarterly if supplied through a backflow or pressure-reducing valve); dry-pipe valve trip; other supervisory devices
Every 3 years—Dry-pipe valve full-flow trip
Every 5 yearsAlarm and check valve interior; backflow assembly interiorGauges

Who may inspect and tag a sprinkler system in Texas?

  • A company with a State Fire Marshal's Office (SFMO/TDI) Sprinkler Certificate of Registration. An RME-General Inspector may perform inspection, testing and maintenance and sign the tag; an RME-General licensee may also install and repair.
  • After each scheduled inspection, test or maintenance service, the company attaches a light blue SFMO tag to each riser, punched for the type of service (initial installation, monthly, quarterly, annual, third year or fifth year), and tags stay on for 5 years (28 TAC §34.720).
  • NFPA 25 makes the building owner responsible for the inspections, tests and maintenance; qualified owner representatives may do many of the routine inspections where the authority having jurisdiction accepts it.

Houston example: what the local fire marshal adds

  • Wet-pipe systems: monthly and quarterly visual inspections by trained building or contract personnel with a written record, and an annual NFPA 25 inspection and test tagged by a licensed sprinkler company (HFD LSB Standard No. 02 §2.5.1).
  • Dry-pipe systems: quarterly visual, annual test and partial trip, full trip every 3 years (§2.5.2).
  • Fire department connections: quarterly inspection, and a hydrostatic or flow test every 5 years (§2.5.4).
  • Outside Houston, ask your city or county fire marshal whether it adds local rules to the NFPA 25 schedule.

Frequently asked questions

How often does a fire sprinkler system need to be inspected in Texas?

On the NFPA 25 (2020 edition) schedule adopted in 28 TAC §34.707: some components weekly or monthly, others quarterly, a full inspection and test annually, and longer tests every 3 and 5 years. A light blue SFMO tag goes on each riser after every scheduled service (28 TAC §34.720).

Which edition of NFPA 25 does Texas use?

NFPA 25, 2020 edition. The State Fire Marshal adopted it in 28 TAC §34.707, effective September 1, 2023.

Does Houston require more than NFPA 25?

Houston's LSB Standard No. 02 §2.5.1 requires written monthly and quarterly visual inspections of wet-pipe systems by trained building or contract personnel, and an annual NFPA 25 inspection and test tagged by a licensed sprinkler company.

Who can sign the sprinkler inspection tag in Texas?

A licensee working for a company with an SFMO/TDI Sprinkler Certificate of Registration: an RME-General Inspector or an RME-General.

How do I get bids for a sprinkler inspection in Texas?

Post the inspection free on FireMarket USA (no card needed to post). Licensed contractors bid, and each bid shows the contractor's license class and insurance status. With FireMarket's AI on, the AI posts the job, licensed contractors bid, the AI awards the top eligible bid, and the winning contractor accepts.

Sources

Sources checked 2026-11-28. Informational only, not legal advice; confirm requirements with your AHJ.

Next step: post the job and compare licensed bids on FireMarket

Post the job on FireMarket USA for free (no card needed to post) and compare bids from Texas SFMO/TDI-licensed contractors. Each contractor's license status is checked when they bid, from FireMarket's weekly re-check of SFMO/TDI records, and the bid shows the license class and certificate-of-insurance status. You can also invite contractors you already use.

Post a sprinkler inspection job free