Texas Fire Sprinkler Contractor License Guide
In Texas, fire sprinkler contractors are regulated by the State Fire Marshal's Office (SFMO), part of the Texas Department of Insurance (TDI), under Texas Insurance Code Chapter 6003 and 28 Texas Administrative Code Chapter 34, Subchapter G (rules 34.700 and following) (SFMO fire sprinkler licensing).
The system has two layers. Companies hold a Sprinkler Certificate of Registration (SCR). Individuals hold a Responsible Managing Employee (RME) license, and an individual license can only be issued to someone employed by a registered company (SFMO license and test information).
Last verified 2026-10-16 against the TDI / SFMO pages and statute listed at the end of this article. Requirements and fees change, so confirm with SFMO before you apply. This guide is educational, not legal or professional advice.
Company registrations
Under Insurance Code §6003.151(a), an individual or organization may not plan, sell, install, maintain, or service a fire protection sprinkler system without a registration certificate from TDI.
| Registration | Who needs it |
|---|---|
| Sprinkler Certificate of Registration – General (SCR-G) | A company that plans, sells, installs, maintains, certifies, or services fire protection sprinkler systems |
| Sprinkler Certificate of Registration – Underground (SCR-U) | A company that sells, installs, maintains, services, or certifies underground water supply piping to fire protection sprinkler systems |
| Sprinkler Certificate of Registration – Dwelling (SCR-D) | A company that plans, sells, installs, maintains, services, and certifies one- or two-family dwelling sprinkler systems |
Source: SFMO fire sprinkler registration, license, and test information.
Each registered contractor must employ at least one licensed Responsible Managing Employee on a full-time basis (Insurance Code §6003.153(a)). If the company loses its RME through death or dissociation, a currently registered company may keep operating for 30 days, or longer if the commissioner approves under the rules (§6003.153(c)). SFMO will not register a company without a licensed employee.
To get an SCR, SFMO requires a Fire Sprinkler Certificate of Registration Application (form SF037), a certificate of liability insurance (see Insurance below), and the individual license or license-transfer form for the RME, all submitted together.
Individual (RME) license types
| License | Work permitted (per SFMO) | Required tests |
|---|---|---|
| RME – General (RME-G) | Plan, install, maintain, service, and certify all types and parts of a fire sprinkler system. Signs design plans and certifications and performs and signs inspection, test, and maintenance tags. | Fire Sprinkler Statutes and Rules (TFM08) and NICET Water-Based Systems Layout Level III. The NICET exams may be waived for a current Professional Engineer. |
| RME – Dwelling (RME-D) | Plan, install, maintain, service, and certify one- or two-family dwelling sprinkler systems | Statutes and Rules (TFM08) and NICET Water-Based Systems Layout Level II |
| RME – Underground (RME-U) | Install, maintain, service, and certify underground water supply piping for sprinkler systems. Planning must be done by another qualified company. | Statutes and Rules (TFM08) and Fire Sprinkler Underground (TFM10, based on NFPA 24). The technical exam may be waived for a current Professional Engineer. |
| RME – General Inspector (RME-I) | Perform the inspection, test, and maintenance service for a fire sprinkler system, and sign the inspection, test, and maintenance tags | Statutes and Rules (TFM08) and NICET Inspection and Testing of Water-Based Systems Level II |
Source: SFMO fire sprinkler registration, license, and test information.
For annual and other NFPA 25 inspection, testing, and maintenance work, SFMO's table shows the RME-G and RME-I as the licenses that perform and sign ITM tags (the RME-D also does so for one- and two-family dwellings).
Insurance Code §6003.002(a) lists who the chapter does not apply to. Examples include a regular employee of a registered sprinkler contractor, a licensed engineer acting solely in a professional capacity, and an installation, maintenance, or service project with a total contract price under $100 that is not part of a larger project or split up to evade the chapter.
Applying for an individual license
Applicants must include a fingerprint receipt unless fingerprints are already on file with SFMO, and must submit the Individual Application for All Types of Fire Sprinkler Licenses (form SF036) (SFMO license and test information). Sprinkler company registrations and individual licenses can be applied for online (SFMO online licensing).
The tests
Per SFMO's license and test information page:
- State tests are scheduled through PSI (psiexams.com/txfire). NICET tests are taken through NICET, and you send SFMO a copy of NICET's completion letter.
- All tests are closed book, with 50 true/false or multiple-choice questions.
- The passing score is 70% or better.
- Each type of test may be scheduled only once a week and no more than three times every 12 months.
- The Statutes and Rules test (TFM08) is based on Insurance Code Chapter 6003 and 28 TAC 34.700.
- All technical tests other than TFM08 are waived for a Texas registered professional engineer. SFMO says a civil engineer license is preferred for an RME-U applicant.
Insurance
To register with SFMO, a company must file a certificate of insurance showing general liability coverage of at least $100,000 combined single limits per occurrence and $300,000 total for the policy year, including products and completed operations coverage. The certificate must list SFMO as certificate holder and be signed by a Texas-licensed general lines or surplus lines agent (SFMO certificate of liability insurance requirements; Insurance Code §6003.152).
SFMO won't approve renewals or new applications until insurance requirements are met. Failure to maintain the required insurance is grounds for denial, suspension, or revocation of the registration after notice and hearing (Insurance Code §6003.152(e)).
Fees
Company certificate of registration fees (initial fees include a $50 application fee)
| Registration | Initial fee | Renewal fee (2 year) |
|---|---|---|
| SCR-General | $950 | $1,800 |
| SCR-Underground | $350 | $600 |
| SCR-Dwelling | $350 | $600 |
Individual license fees
| License | Initial fee | Renewal fee (2 year) |
|---|---|---|
| RME-General | $200 | $350 |
| RME-Dwelling | $150 | $200 |
| RME-Underground | $150 | $200 |
| RME-General Inspector | $50 | $100 |
Source: SFMO fire sprinkler registration, license, and test information. SFMO lists a $35 fee to revise a registration or to get a duplicate, revised, or transferred individual license. Fees are nonrefundable except for overpayments from mistakes of law or fact. PSI and NICET exam fees are separate.
Renewal
- An initial registration certificate or license is valid for one year from the date of issue (and may be issued for less, with the fee prorated). A renewal is valid for two years (Insurance Code §6003.201).
- SFMO sends a renewal notice 90 days before a license expires (SFMO license and test information). Renewals are done online through Sircon (SFMO fire sprinkler licensing).
- Expired 90 days or less: pay the renewal fee plus one-half of the initial fee. Expired more than 90 days but less than two years: pay all unpaid renewal fees plus a fee equal to the initial fee. Expired two years or longer: no renewal; apply as new (Insurance Code §6003.203).
- Since 1/9/2026, if an SFMO license has expired and you have no other active SFMO license on file, you must submit new fingerprints before it can be renewed or reinstated (SFMO fire industry licensing).
Continuing education: Insurance Code §6003.158 lets the commissioner certify continuing education programs and states that participation is voluntary. We did not find a state CE-hour requirement for RME renewal on the SFMO pages listed below.
Reciprocity: TDI may waive any license requirement for an applicant licensed in another state with substantially equivalent requirements (Insurance Code §6003.159).
Verifying a sprinkler contractor
Use the SFMO company / licensee search to look up a company or individual. Check that:
- The company holds an active Sprinkler Certificate of Registration of the right type (General, Underground, or Dwelling) for the work.
- The person who will sign the inspection, test, and maintenance tags holds an RME-G or RME-I (or an RME-D for one- and two-family dwellings).
Two statutory checks are easy to do on paper. Every bid, proposal, offer, and installation drawing for a sprinkler system must prominently display the contractor's registration certificate number (Insurance Code §6003.155), and each registration certificate and license must be posted in a conspicuous place at the contractor's place of business (§6003.154).
SFMO now sends licenses and registrations only by email, and paper licenses and pocket cards are no longer provided (SFMO fire sprinkler licensing). The online search is the place to confirm status. Unlicensed work can be reported to SFMO Licensing Investigations.
Knowingly violating the registration or RME requirements (§6003.151(a) or §6003.153) or the prohibited-practices section (§6003.251) is a Class B misdemeanor (Insurance Code §6003.301).
Sprinkler work in Houston on FireMarket
Create a service provider account on FireMarket to bid on open Houston jobs, and so property managers can also invite you to jobs or send you a private job link. Bid yourself, or turn on AI Auto-Bid: it prices bids from your own rates, and in auto mode it submits them for you (preview mode stages them for one-click review). Your bids show your TX SFMO/TDI license class and a Verified or Failed/expired badge, re-checked weekly and shown at bid (not a live feed).
Sources
All pages fetched and checked on 2026-10-16.
- TDI / SFMO, Fire sprinkler licensing: https://www.tdi.texas.gov/fire/fmlisprinkler.html
- TDI / SFMO, Fire sprinkler registration, license, and test information (registrations, RME types, tests, fees): https://www.tdi.texas.gov/fire/information-fire-sprinkler-registration-license-test.html
- TDI / SFMO, Certificate of liability insurance requirements: https://www.tdi.texas.gov/fire/certificate-liability-insurance.html
- TDI / SFMO, Apply or renew fire safety licenses: https://www.tdi.texas.gov/fire/online-licensing.html
- TDI / SFMO, Fire industry licensing (fingerprint notice): https://www.tdi.texas.gov/fire/fmli.html
- TDI / SFMO, Company / licensee search: https://appscenter.tdi.texas.gov/reports/p/sfmo
- Texas Insurance Code Chapter 6003, Fire Protection Sprinkler System Service and Installation: https://statutes.capitol.texas.gov/Docs/IN/htm/IN.6003.htm
- 28 Texas Administrative Code Chapter 34, Subchapter G, Fire Sprinkler Rules: https://texas-sos.appianportalsgov.com/rules-and-meetings?chapter=34&interface=VIEW_TAC&part=1&subchapter=G&title=28
Last verified 2026-10-16.
Informational only, not legal advice. Confirm current requirements with the Texas Department of Insurance / State Fire Marshal's Office and your local authority having jurisdiction.