By Dave Maloney · Last reviewed 2026-10-16. Informational only, not legal advice.

Texas Fire Alarm Contractor License Guide

In Texas, fire alarm and fire detection work is regulated by the State Fire Marshal's Office (SFMO), part of the Texas Department of Insurance (TDI), under Texas Insurance Code Chapter 6002 and 28 Texas Administrative Code Chapter 34, Subchapter F (rules 34.600 and following) (SFMO fire alarm licensing).

The system has two layers. Companies hold a certificate of registration. Individuals hold a license, and an individual license can only be issued to someone employed by a registered company (SFMO license and test information).

Last verified 2026-10-16 against the TDI / SFMO pages and statute listed at the end of this article. Requirements and fees change, so confirm with SFMO before you apply. This article is educational, not legal or professional advice.


Company registrations

Under Insurance Code §6002.151, an individual or organization may not engage in the business of planning, certifying, leasing, selling, installing, servicing, monitoring, or maintaining fire alarm or fire detection devices or systems without a registration certificate from TDI.

Registration Who needs it
Alarm Certificate of Registration (ACR) A company that plans, certifies, leases, sells, services, installs, monitors, or maintains fire detection devices or systems. The work the company may do depends on the licenses its employees hold.
Alarm Branch Office Certificate of Registration (ACR – Branch Office) Each separate office location doing the same business as the company with the ACR.
Alarm Certificate of Registration – Single-Station (ACR-SS) A company that works only with single-station devices.

Source: SFMO fire alarm registration, license, and test information.

To get an ACR, SFMO requires:

  • A Fire Alarm Certificate of Registration application (form SF031).
  • A certificate of liability insurance (see Insurance below).
  • A designated full-time employee who holds a Fire Alarm Technician, Fire Alarm Planning Superintendent, or Residential Fire Alarm Superintendent license. A Residential Fire Alarm Technician license alone is not enough.

SFMO will not register a company without a licensed employee. New fire alarm company registrations are filed on PDF forms rather than online (SFMO online licensing).


Individual license types

License Work permitted (per SFMO) Required tests
Fire Alarm Planning Superintendent (APS) Sell, plan, install, certify, service, and monitor all types of fire alarm or detection devices or systems Statutes and Rules (TFM11), plus one of: ESA Level III Fire Alarm Designer certification, NICET Level III Fire Alarm Systems, or Texas Professional Engineer license
Fire Alarm Technician (FAL) Sell, install, certify, service, and monitor all types of fire alarm or detection devices or systems. No planning. Statutes and Rules (TFM11) and Fire Alarm Technician (TFM12). TFM12 can be replaced by ESA Level II Fire Alarm Technician certification or NICET Level II.
Fire Alarm Monitoring Technician (AMT) Monitor residential or commercial fire alarm or detection devices or systems only Statutes and Rules (TFM11) and Fire Alarm Monitoring (TFM14)
Residential Fire Alarm Superintendent (RAS) Sell, plan, install, certify, service, and monitor in one- and two-family dwellings; may also perform all FAL functions Statutes and Rules (TFM11), Fire Alarm Technician (TFM12, or ESA / NICET Level II), and Fire Alarm Residential (TFM13)
Residential Fire Alarm Superintendent – Single Station (RAS-SS) Sell, plan, install, certify, and service only single-station heat or smoke detectors not connected to any other device or system, in one- or two-family dwellings Statutes and Rules (TFM11) and Fire Alarm Residential (TFM13)
Residential Fire Alarm Technician (RAL) Install, service, inspect, and certify residential single-family or two-family fire alarm or detection systems A residential fire alarm technician course from an SFMO-approved training school (no state test listed)

Source: SFMO fire alarm registration, license, and test information. SFMO notes that "certify" means certifying the system meets Chapter 6002 requirements, and "service" includes inspecting, maintaining, repairing, or testing.

Two statutory points worth knowing:

  • A licensed individual must be an employee or agent of a registered company to do licensed work (Insurance Code §6002.154(c)).
  • An employee of a registered firm working under the direct on-site supervision of a license holder is exempt from the licensing provisions (Insurance Code §6002.155(8)).

Applying for an individual license

Before submitting a new license application, the applicant must pass all required tests and have a fingerprint background check on file with SFMO (SFMO license and test information). SFMO accepts online applications through Sircon for the FAL, RAL, RAS, APS, AMT, and RAS-SS licenses (SFMO fire alarm licensing).


The tests

Per SFMO's license and test information page:

  • Tests are scheduled through PSI (psiexams.com/txfire).
  • All tests are closed book, with 50 true/false or multiple-choice questions.
  • The passing score is 70% or better.
  • Each type of test may be scheduled only once a week and no more than three times every 12 months.
  • The Statutes and Rules test (TFM11) is based on Insurance Code Chapter 6002 and 28 TAC 34.600.
  • The Fire Alarm Technician test (TFM12) covers NFPA 72 (except the household fire alarm chapter), plus listed articles and standards including NFPA 70 Articles 760 and 300.
  • Technical tests other than TFM11 may be waived for a professional engineer licensed in Texas.

Insurance

To register with SFMO, a company must file a certificate of insurance showing general liability coverage of at least $100,000 combined single limits per occurrence and $300,000 total for the policy year, including products and completed operations coverage. The certificate must list SFMO as certificate holder and be signed by a Texas-licensed general lines or surplus lines agent (SFMO certificate of liability insurance requirements; Insurance Code §6002.153).

SFMO says registered companies with an expired insurance certificate are in violation and no longer appear in its search, and it won't approve renewals or new applications until insurance requirements are met. Failure to maintain the required insurance is grounds for denial, suspension, or revocation of the registration after notice and hearing (Insurance Code §6002.153(e)).


Fees

Company certificate of registration fees

Registration Initial fee Renewal fee (2 year)
Main office $500 $1,000
Branch office (each) $150 $300
Single-Station only $250 $500

Individual license fees

License Initial fee Renewal fee (2 year)
Fire Alarm Planning Superintendent (APS) $120 $200
Fire Alarm Technician (FAL) $120 $200
Fire Alarm Monitoring Technician (AMT) $120 $200
Residential Fire Alarm Superintendent (RAS) $120 $200
Residential Fire Alarm Superintendent – Single Station (RAS-SS) $120 $200
Residential Fire Alarm Technician (RAL) $50 $100

Source: SFMO fire alarm registration, license, and test information. SFMO lists a $20 fee to revise a registration or to get a duplicate or revised individual license. Fees are nonrefundable except for overpayments from mistakes of law or fact. PSI exam fees are separate and set by PSI.


Renewal

  • A renewed registration certificate or license is valid for two years (Insurance Code §6002.201(a)).
  • SFMO sends a renewal notice 90 days before a license expires (SFMO license and test information). Renewals are done online through Sircon (SFMO fire alarm licensing).
  • A certificate or license expired 90 days or less can be renewed with the renewal fee plus a late fee. One expired more than 90 days but less than two years needs all unpaid renewal fees plus a late fee. After two years expired, it cannot be renewed and the holder must apply as new (Insurance Code §6002.203).
  • Since 1/9/2026, if an SFMO license has expired and you have no other active SFMO license on file, you must submit new fingerprints before it can be renewed or reinstated (SFMO fire industry licensing).

Continuing education: Insurance Code §6002.159 lets the commissioner certify continuing education programs and states that participation is voluntary. We did not find a state CE-hour requirement for fire alarm license renewal on the SFMO pages listed below.


Verifying a fire alarm company or licensee

Use the SFMO company / licensee search to look up a company or individual. Check that:

  • The company holds an active Alarm Certificate of Registration (or ACR-SS if the job is single-station only).
  • The person doing the work holds a license that covers it. For example, an FAL cannot plan a system, and an AMT may only monitor.

SFMO now sends licenses and registrations only by email, and paper licenses and pocket cards are no longer provided (SFMO fire alarm licensing). The online search is the place to confirm status.

Violating the registration or license requirements (§§6002.151, 6002.152, or 6002.154) is a Class B misdemeanor (Insurance Code §6002.351).


Fire alarm work in Houston on FireMarket

Create a service provider account on FireMarket to bid on open Houston jobs, and so property managers can also invite you to jobs or send you a private job link. Your bids show your TX SFMO/TDI license class and a Verified or Failed/expired badge, re-checked weekly and shown at bid (not a live feed).


Sources

All pages fetched and checked on 2026-10-16.

Last verified 2026-10-16.


Informational only, not legal advice. Confirm current requirements with the Texas Department of Insurance / State Fire Marshal's Office and your local authority having jurisdiction.

I manage properties · More Texas fire compliance guides